Logging & monitoring

Every run leaves two records: one row in an SQLite database (the full history) and a rewritten JSON state file (the current picture, for external monitoring to scrape). Both paths are set in [logging].

Database State file
Default path /var/lib/hpc_eff/history.db /var/lib/hpc_eff/state.json
Retention unbounded, one row per run last history_length entries (default 10)
Written append rewritten in full each run
Permissions root-owned chmod 644
For analysis, tuning, reporting dashboards, Prometheus textfile, Icinga checks

There is no log file. Cron discards stdout and stderr (>/dev/null 2>&1), so anything the run printed is gone: these two records are your only evidence that a scheduled run happened at all.


The database

One table, hpc_eff_log, one row per evaluation:

sudo sqlite3 /var/lib/hpc_eff/history.db ".schema hpc_eff_log"
Column Unit Written in Meaning
id always autoincrement
timestamp UTC ISO 8601 always when the row was inserted
hostname always socket.gethostname()
freq_min kHz both modes always 0 (a placeholder, not a real minimum)
freq_max kHz both modes the cap actually applied this run
score_name, score_value always node's benchmark label/score, set manually in [SYSTEM]; see configuration.md
price CZK/MWh co2 current spot price
co2_current gCO₂eq/kWh co2 current grid carbon intensity
co2_median gCO₂eq/kWh co2 median of the last 24 h
co2_grade 1–10 co2 CO₂ percentile grade, TEXT column, holds unknown when the API failed
power_w W co2 instantaneous node power from POWERREADINGCMD
cpu_freq_current MHz co2 frequency observed before this run's change
rating 1–10 always the combined rating that chose freq_max
rating_price 1–10 co2 price component; NULL if the price fetch failed
rating_co2 1–10 co2 CO₂ component; NULL if the CO₂ fetch failed
temperature °C temperature the sensor reading
gpu_power_limit W temperature limit in effect this run (== gpu_target_power)
gpu_target_power W temperature limit this run aimed for
gpu_state temperature HIGH / MID / LOW / UNKNOWN
gpu_count temperature GPUs found
gpu_changed, gpu_success 0/1 temperature whether a change was attempted and whether it worked

Mind the units: freq_max is kHz, cpu_freq_current is MHz. They differ by 1000 and both describe frequency, which makes them easy to plot against each other incorrectly.

Columns belonging to the inactive mode stay NULL. A co2-mode node has NULL temperature and NULL gpu_* for its whole life; that is expected, not a fault.

Schema migration

Nothing to do by hand. On every start hpc-eff renames a legacy cpu_settings_log table to hpc_eff_log and ALTER TABLEs in any column the schema has gained since the file was created. History is preserved in place.

Size

One row per run: roughly 52 000 rows/year at a 10-minute interval, a handful of megabytes. There is no automatic pruning. If it matters, rotate it yourself:

sudo sqlite3 /var/lib/hpc_eff/history.db \
  "DELETE FROM hpc_eff_log WHERE timestamp < date('now','-1 year'); VACUUM;"

The state file

{
  "static": {
    "score_name": "SPEC2017",
    "score_value": 3.8,
    "power_cmd": "ipmitool dcmi power reading",
    "plugins": { "power": "power_reader.py", "price": "energy_price.py",
                 "co2": "co2_value.py", "temperature": "cpu_thermo.py" }
  },
  "current": {
    "timestamp": "2026-08-21T10:00:03Z",
    "rating": 5, "rating_price": 6, "rating_co2": 4,
    "selected_freq_khz": 2600000,
    "action_price": "Price 2431 is average; Combined rating 5 (price 6, CO2 4)",
    "price": 2431, "co2_current": 412, "co2_median": 448, "co2_grade": 4,
    "power_w": 287, "cpu_freq_current": 2712
  },
  "history": [ "…same shape, newest first, up to history_length entries…" ]
}

current is a copy of history[0]. static is refreshed every run, so it also serves as a liveness marker for the config the node is running with.

The example above is a co2-mode node. A temperature-mode node carries temperature, thermo_freq_limit, and action_temp instead, plus the gpu_* fields on GPU nodes; the price and rating keys are absent entirely.

action_price (and action_temp in temperature mode) is the human-readable summary of what the run decided: the fastest thing to eyeball when something looks wrong. action_temp exists only here, not in the database, so it is the only place a thermal failure explains itself.

The file is world-readable and rewritten atomically enough for polling. A stale-state check only needs current.timestamp compared against now; alert if it's older than a few cron intervals.


Queries worth having

Most of these read the co2-mode columns; the temperature-mode ones are further down.

Is it running, and is it healthy?

SELECT date(timestamp) AS day,
       COUNT(*)                  AS runs,
       SUM(rating_price IS NULL) AS price_fail,
       SUM(rating_co2 IS NULL)   AS co2_fail,
       ROUND(AVG(rating), 2)     AS avg_rating
FROM hpc_eff_log
GROUP BY day ORDER BY day DESC LIMIT 14;

144 runs/day at a 10-minute interval. avg_rating pinned at exactly 5 with both failure counts high means the node is not regulating at all: it is falling back to the neutral rating every cycle.

How much time is spent at each cap?

SELECT freq_max/1000 AS mhz,
       COUNT(*)      AS runs,
       ROUND(100.0*COUNT(*)/(SELECT COUNT(*) FROM hpc_eff_log), 1) AS pct
FROM hpc_eff_log
WHERE freq_max IS NOT NULL
GROUP BY mhz ORDER BY mhz DESC;

If one row holds >90 % of the time, the frequency table is too coarse or the rating never moves; revisit deployment.md.

Did the weights do anything?

SELECT rating_price, rating_co2, rating, COUNT(*) AS n
FROM hpc_eff_log
WHERE rating_co2 IS NOT NULL
GROUP BY rating_price, rating_co2, rating
ORDER BY n DESC LIMIT 20;

This is the table to tune weight_price/weight_co2 against: it shows how often the CO₂ term actually shifted the combined rating away from the price rating. If rating equals rating_price in nearly every row, the CO₂ signal is not earning its weight on your grid.

Daily profile: when is the node throttled?

SELECT strftime('%H', timestamp) AS hour_utc,
       ROUND(AVG(rating), 2)     AS avg_rating,
       ROUND(AVG(freq_max)/1000) AS avg_mhz
FROM hpc_eff_log
GROUP BY hour_utc ORDER BY hour_utc;

Rough energy accounting

SELECT date(timestamp) AS day,
       ROUND(AVG(power_w))                     AS avg_w,
       ROUND(AVG(power_w) * 24 / 1000.0, 1)    AS approx_kwh,
       ROUND(AVG(power_w) * 24 / 1000.0 * AVG(co2_current) / 1000.0, 2) AS approx_kg_co2
FROM hpc_eff_log
WHERE power_w IS NOT NULL
GROUP BY day ORDER BY day DESC LIMIT 30;

Estimate only, not metering-grade: power_w is one BMC sample per cron interval, assumed to hold for the whole interval.

Temperature-mode queries

Health check, the equivalent of the first query above:

SELECT date(timestamp) AS day,
       COUNT(*)                     AS runs,
       SUM(temperature IS NULL)     AS read_fail,
       ROUND(MIN(temperature), 1)   AS min_c,
       ROUND(MAX(temperature), 1)   AS max_c,
       COUNT(DISTINCT freq_max)     AS caps_used
FROM hpc_eff_log
GROUP BY day ORDER BY day DESC LIMIT 14;

Any read_fail at all means the sensor was unreadable and no cap was applied that run — there is no fallback in this mode. caps_used of 1 in a stable room is the intended steady state, not a fault; caps_used of 3 every day means your limits sit below the room's normal range.

Where the bands actually sit, which is how you re-tune MID_LIMIT/HIGH_LIMIT against real readings rather than guesses:

SELECT freq_max/1000            AS mhz,
       COUNT(*)                 AS runs,
       ROUND(MIN(temperature),1) AS min_c,
       ROUND(MAX(temperature),1) AS max_c
FROM hpc_eff_log
WHERE temperature IS NOT NULL
GROUP BY mhz ORDER BY mhz DESC;

GPU regulation, if you have it:

SELECT gpu_state, COUNT(*) AS runs,
       SUM(gpu_changed) AS changes,
       SUM(gpu_success = 0) AS failures
FROM hpc_eff_log
WHERE gpu_count > 0
GROUP BY gpu_state;

gpu_state stuck at HIGH forever usually means the [GPU_POWER] thresholds (70/80 °C by default) sit above anything the shared sensor ever reports. Compare them against the temperature column; see troubleshooting.md.

Fleet-wide

hostname is on every row, so per-node databases can be scp'd in and combined with SQLite's ATTACH: one INSERT ... SELECT per node into a shared table.


Reading the database on a running node

The database is opened in WAL mode, so concurrent reads are safe: you do not need to stop cron, and you do not need to copy the file first:

sudo sqlite3 -readonly /var/lib/hpc_eff/history.db "SELECT * FROM hpc_eff_log ORDER BY id DESC LIMIT 5;"

If you do want a copy, take it properly (a plain cp of a WAL database can miss the most recent transactions):

sudo sqlite3 /var/lib/hpc_eff/history.db ".backup /tmp/history.db"